Epson Stylus Photo 750 Specifications Page 62

  • Download
  • Add to my manuals
  • Print
  • Page
    / 114
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 61
EPSON Stylus Photo 750 Revision A
Disassembly and Assembly Disassembly 57
4.2.3 Control Panel Removal
1. Remove the upper housing.(See“Housing Removal” on page -54)
2. Remove 2 screws securing the control panel, then remove the
control panel from the printer mechanism.
3. Remove one screw securing the “Housing, Panel, Left” to the printer
mechanism.
4. Remove 2 screws securing the “Board, Assembly, Panel” to the
printer mechanism, then remove C209PNL board from the “Panel,
Assembly”.
5. Remove FFC from the connector on the C209PNL board.
Figure 4-5. Control Panel Removal
CHECK
PO INT
By removing the control panel, the stacker assembly
can be also detached from the printer mechanism,
since it is held by the control panel assembly.
Shield Plate, Panel
Board Assem bly, Panel
Panel Assem bly
Stacker, Assem bly
H ousing, Panel, Left
Page view 61
1 2 ... 57 58 59 60 61 62 63 64 65 66 67 ... 113 114

Comments to this Manuals