EPSON Stylus Scan 2000
4 -
EPSON Stylus Scan 2000
9/99
Image data 12 bits per pixel per color internal
8 bits per pixel per color external
Brightness 7 levels
Line art settings Fixed threshold [CORRECT?]
Text Enhancement Technology
Halftoning process AAS (Auto Area Segmentation)
Gamma correction Printer 3 level (A, B, C)
User defined 1 level
Interface USB 1.0 + IEEE 1284.4
Light source White cold cathode fluorescent lamp
Reliability Main unit life: 10,000 pages
Lamp life: 10,000 hours
Electrical
Environmental
Temperature Operation: 50 to 95 °F (10 to 35 °C)
Storage*: –4 to 104 °F (–20 to 40 °C)
1 month at 104 °F (40 °C)
Transit*: –4 to 140 °F (–20 to 60 °C)
120 hours at 140 °F (60 °C)
Humidity Operation: 20 to 80% RH
Storage*: 5 to 85% RH (without
condensation)
* Stored in shipping container
Safety Approvals
Safety standards UL 1950 with D3, CSA 22.2 No. 950
EMC FCC part 15 subpart B class B
Interfaces
USB interface
Parallel interface
Specification 120V model 240V model
Input voltage range 99V to 132V 198V to 264V
Rated frequency range 50 to 60 Hz
Input frequency range 49.5 to 60.5 Hz
Rated current 0.6A 0.4A
Power consumption Approx. 29 W (ISO 10561 Letter Pattern)
Specification Description
Standard Based on Universal Serial Bus Specifications
Revision 1.0, Universal Serial Bus Device Class
Definition for Printing Devices Version 1.0
Bit rate 12 Mbps (full speed device)
Data encoding NRZI
Adaptable connector USB Series B
Recommended
cable length
6.5 feet (2 meters) maximum
Forward channel
Specification Description
Data format 8-bit parallel, IEEE-1284 compatibility mode
Synchronization Refer to the IEEE-1284 specification
Handshake timing Refer to the IEEE-1284 specification
Signal level IEEE-1284 Level 1 device
Connector 57-30360 Amphenol connector or equivalent
Reverse channel
Specification Description
Transmission mode IEEE-1284 Nibble mode, IEEE-1284 ECP mode
Adaptable connector 57-30360 Amphenol connector or equivalent
Synchronization Refer to the IEEE-1284 specification
Handshaking Refer to the IEEE-1284 specification
Signal level IEEE-1284 Level 1 device
Data transmission
timing
Refer to the IEEE-1284 specification