3.73.BiSetEtherEchoTime
[Function]
Sets the number of network printer response confirmations and the length of 1 time out after opening the StatusAPI.
[Format]
int BiSetEtherEchoTime( int nHandle, BYTE Count, WORD Timeout)
[Argument]
int nHandle
Specifies the handle value of the printer to change the interval. The BiOpenMonPrinter() return value is used in the handle
value.
BYTE Count
Specifies the number of response confirmations. (0 < Count
≤
255)
WORD Timeout
Specifies the length of 1 time out (Millisecond units (0 < Timeout ≤ 65535)
[Return value]
0 is returned when changing the interval to get information from the printer is successful. The following error codes (less than
zero) are returned when an error is triggered.
ERR_HANDLE The handle value specified for the printer is incorrect.
ERR_PARAM Specified interval in milliseconds is less than or equal to zero.
ERR_REGISTRY Registry Error
[Explanation]
If a value is not specified by this function, the value set by BiSetDefaultEchoTime ( ) becomes the effective value. If it has not
been set by BiSetDefaultEchoTime ( ), the number of times is et at 1 and the time out duration becomes 1 second. This
function is enabled only when connected through Ethernet.
[Supported printer]
TM-T88II, TM-T88III, TM-T90, TM-L90, TM-H5000II, TM-U590, TM-U675, TM-H6000, TM-H6000II, TM-J8000,
TM-J2000/2100, TM-J7000/7100, TM-U230, TM-U210A, TM-U325, TM-U950, TM-U295, TM-L60II