Epson FEH300b User Manual

Browse online or download User Manual for Unknown Epson FEH300b. Epson FEH300b User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Hardware

FEH300bDisplay Attached [email protected] for MCUSER'S MANUALHardware

Page 2

1-21-2 [email protected] for MC is composed of a programmable operation display (the display unit) and a controller unit attached tothe back of t

Page 3 - Safety Precautions

1-31-3 Types• @E.Terminal for MCProduct types Display size SpecificationsNP5M0101-5H4 12.1 inches• TFT color, 800 x 600 dots, DC power supply• Contro

Page 4

1-41-3 Types• Auxiliaries and othersNames Types SpecificationsBattery for display unit V7-BT Replacement lithium primary battery for the V8 seriesRep

Page 5

1-51-4 System CompositionThe following illustration shows the system composition of @E.Terminal for [email protected] for MCScreen editor "V-SFT-5&

Page 6 - Revisions

Section 2 SpecificationsPage2-1 Specifications...

Page 7 - Contents

2-1Section 2 Specifications2-1 Specifications2-1-1 General specificationsItemsSpecificationsNP5M0101-5H4NP5N0011-5H4NP5M0101-4H4NP5N0011-4H4NP5M0101

Page 8 - Section 1 General

2-22-1 Specifications2-1-2 Display unit specifications(1) Display unit specificationsItemNP5M0101-5H4NP5N0011-5H4NP5M0101-4H4NP5N0011-4H4NP5M0101-3H4

Page 9

2-32-1 Specifications(4) Interface specificationsItem SpecificationsD-sub 9-pin (CN1) ApplicablestandardsRS-232C, RS-422/485Synchronization Asynchron

Page 10 - 1-2 Appearance

2-42-1 Specifications(6) Drawing environmentItem SpecificationsDrawing method Exclusive configuration softwareDrawing tool Name of exclusive configur

Page 11 - 1-3 Types

2-52-1 Specifications(8) Function performance specificationsItem SpecificationsScreens Max. 1024Screen memory Flash memory: Approx. 12.5 Mbytes (Vari

Page 12

PrefaceThis hardware edition of the user’s manual describes system composition, specifications, and handling of the @E.Terminal.In order to operate th

Page 13 - 1-4 System Composition

2-62-1 Specifications2-1-3 Controller unit specifications(1) Application performance specificationsItem SpecificationsType NP5M0101-5H4/4H4/3H4 NP5N0

Page 14

2-72-1 Specifications(2) Specific system memoryThe table below lists system memory specific to @E.Terminal controller unit.[Expansion annunciator rel

Page 15 - Section 2 Specifications

2-82-2 Dimensions and Panel Cut-outNote: Arrange SX bus expansion cable so thatradius of bend in the cable is at least 50mm.Plug/unplug the SX bus ex

Page 16 - 2-1 Specifications

2-92-2 Dimensions and Panel Cut-outNote: Arrange SX bus expansion cable so thatradius of bend in the cable is at least 50mm.Plug/unplug the SX bus ex

Page 17

2-102-2 Dimensions and Panel Cut-out2-2-3 External dimensions and panel cut-out dimensions for the NP5M0101-3H4/NP5N0011-3H4(Unit: mm)CN124VDCFGCN522

Page 18

2-112-3 Names and Functions2-3-1 Display unit(1) NP5M0101-5H4/NP5N0011-5H41)2)3)4)17)15)14)13)12)11)10)9)5)7)8)16)6)CN5CN7 CFU-B U-ALANCN1MJ2MJ1F 7F

Page 19

2-12(3) NP5M0101-3H4/NP5N0011-3H49)10) 11)12)13)14) 15)1)2)3)4)5)7)8)16)6)17)LANU-BU-ACN124VDCFGCN5CN7CFMJ1MJ21) DisplayThis is the display unit.2) Po

Page 20

2-132-3 Names and Functions9) Power supply terminal block (display unit)Supplies the power to the display unit (24 V DC).10) Modular jack 1 (MJ1)Used

Page 21

2-142-3-2 Controller unit4:RUN3:U-TERM2:TERM1:STOPONLERRUROMRUNALMBATUSBLOADERUSER ROM CARDSX-BUSINOUTNo.CPU24V DC+-FG4) Data backup battery2) Key swi

Page 22 - (Unit: mm)

2-152-3 Names and Functions1) Status indication LED (Controller unit)Symbol Color DescriptionsONLERRGreenRedStatus of the controller unit.<Lights

Page 23

Safety PrecautionsBe sure to read the “Safety Precautions” thoroughly before using the module.Here, the safety precaution items are classified into “W

Page 24

2-162-4 Serial ConnectorCommunication (RS-232C, RS-422/485) with a controller is enabled via the serial connector (CN1).• For NP5M0101-5H4/4H4NP5N001

Page 25 - 2-3 Names and Functions

2-172-5 Modular Jack (MJ1 / MJ2)A screen data transfer cable (MJ1 only), temperature controller, barcode reader, CREC, or V-I/O can be connected to t

Page 26

2-182-6 Dip SwitchesIn NP5M0101-5H4/4H4, NP5N0011-5H4/4H4, the dip switch is hidden by the controller unit.Operate the dip switch by detaching the co

Page 27

2-192-6 Dip SwitchesDip switch number 2 (CF Card interface cover access control)When the dip switch number 2 is set to the ON position, access to the

Page 28

Section 3 InstallationPage3-1 Mounting Procedure ...

Page 29

3-1Section 3 Installation3-1 Mounting Procedure(1) Mounting procedure1) Insert the @E.Terminal unit into the mounting panel (max. thick: 5 mm).XYNP5

Page 30 - 2-4 Serial Connector

3-23-2 Power Supply Cable WiringWarningElectric shock hazard. Shut the power off before wiring the power supply cable. (1) Power supply cable wiringP

Page 31 - 2-5 Modular Jack (MJ1 / MJ2)

3-3• Tighten terminal screws on the power supply terminal block of the display unit with the following torque.Use a power supply cable within the rang

Page 32 - 2-6 Dip Switches

3-43-2 Power Supply Cable Wiring(2) GroundingCaution Be sure to establish a ground of the @E.Terminal. (The level of grounding resistance should be

Page 33 - 0.5 to 0.7N·m

Section 4 Inspection and MaintenancePage4-1 Inspection and Maintenance ...

Page 34 - Section 3 Installation

Safety PrecautionsCaution◊ Check the appearance of the unit when it is unpacked. Do not use the unit if any damage or deformation is found. Failure t

Page 35

4-1Section 4 Inspection and Maintenance4-1 Inspection and MaintenanceWarningBe sure to turn off the power before conducting inspection or maintenanc

Page 36 - Grounding

4-24-2 Battery ReplacementWhen the time comes to replacement the battery, replace it for a new one even if battery error is not displayed.Also, when

Page 37 - Terminal dimensions

4-34-2 Battery ReplacementBattery replacement• Battery replacement of display unit1) Remove the controller unit from @E.Terminal.Remove mounting scre

Page 38 - Caution

4-44-3-1 Ordering notesWhen ordering electrical and control equipment (or requesting price estimates), the following general notes are to beobserved,

Page 39

Appendix 1 About Project for @E.Terminal (No contents installed)PageAppendix 1 About Project for @E.Terminal (No contents installed) ...

Page 40 - 4-1-2 Periodical inspection

App. 1-1Appendix 1 About Project for @E.Terminal(No contents installed)When you make new project for controller of @E.Terminal (No contents installed)

Page 41 - 4-2 Battery Replacement

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032,JapanPhone: +81-3-5435-7280Fax: +81-3-5435-7425URL http://www.fesys.c

Page 42

Safety Precautions[General Notes]• Never bundle control cables nor input/output cables with high-voltage and large-current carrying cables such aspowe

Page 43 - 4-3 Maintenance Services

*Manual No. is shown on the cover.Printed on *Manual No. Revision contentsAug. 2008 FEH300 First editionNov. 2008 FEH300a • Display part is changed fr

Page 44 - (No contents installed)

ContentsPrefaceSafety PrecautionsRevisionsContentsPageSection 1 General ...

Page 45 - (No contents installed)

Section 1 GeneralPage1-1 Overview of @E.Terminal for MC...... 1-11-2 Appea

Page 46 - Fax: +81-3-5435-7425

1-1Section 1 General1-1 Overview of @E.Terminal for MCThe @E.Terminal for MC Display Attached Controller is an all-in-one programmable operation dis