1127.8700.12-03- 2Test and MeasurementDivisionOperating ManualVECTOR NETWORKANALYZERZVR / ZVRE / ZVRL1127.8551.61/.621127.8551.51/.521127.8551.41ZVC /
Contents ZVx1127.8700.12 18 E-35.5.3 Testing the Test Set Specifications...
ZVx INITiate Subsystem1043.0009.50 3.61 E-153.6.8 INITiate SubsystemThe INITiate subsystem controls the initialization of the trigger subsystem. COMMA
INPut Subsystem ZVx1043.0009.50 3.62 E-153.6.9 INPut SubsystemThe INPut subsystem controls the features of the input of the instrument. COMMAND PARAME
ZVx INSTrument Subsystem1043.0009.50 3.63 E-153.6.10 INSTrument SubsystemThe INSTrument subsystem selects the measuring mode of the instrument either
MMEMory Subsystem ZVx1043.0009.50 3.64 E-153.6.11 MMEMory SubsystemThe MMEMory (mass memory) subsystem provides the commands which allow for access to
ZVx MMEMory Subsystem1043.0009.50 3.65 E-15 COMMAND PARAMETER UNIT COMMENT:SELect[:ITEM]:GSETup:HWSettings:LINes[:ALL]:CSETup:CDATa:CKData:HCOPy:MACRo
MMEMory Subsystem ZVx1043.0009.50 3.66 E-15MMEMory:DATAThis command writes block data to a specified file.Syntax:MMEMory:DATAMMEMory:DATA?<file_nam
ZVx MMEMory Subsystem1043.0009.50 3.67 E-15MMEMory:LOAD:STATeThis command loads instrument settings from files.Syntax: MMEMory:LOAD:STATe 1,<file_n
MMEMory Subsystem ZVx1043.0009.50 3.68 E-15MMEMory:NAMEThis command specifies a file which is printed or plotted.Syntax: MMEMory:NAME <file_name>
ZVx MMEMory Subsystem1043.0009.50 3.69 E-15MMEMory:CLEar:ALLThis command deletes all device settings in the current directory.Syntax: MMEMory:CLEar:AL
MMEMory Subsystem ZVx1043.0009.50 3.70 E-15MMEMory:SELect[:ITEM]:CSETupThis command includes the current screen color settings in the list of partial
ZVx Contents1127.8700.12 19 E-3Annex A - Interfaces ...
ZVx MMEMory Subsystem1043.0009.50 3.71 E-15MMEMory:SELect[:ITEM]:AFILesThis command includes the ASCII data sets generated in the list of partial data
OUTPut Subsystem ZVx1043.0009.50 3.72 E-153.6.12 OUTPut SubsystemThe OUTPut subsystem controls the output features of the analyzer. COMMAND PARAMETER
ZVx OUTPut Subsystem1043.0009.50 3.73 E-15OUTPut:UPORt<1|2>[:VALue]This command sets the control lines of the user port. If the user port was se
PROGram - Subsystem ZVx1043.0009.50 3.74 E-153.6.13 PROGram - SubsystemThe PROGram-subsystem contains commands used to start and control application
ZVx PROGram - Subsystem1043.0009.50 3.75 E-15PROGram[:SELected]:EXECuteThis command executes the specified command in the selected application.Syntax:
SENSe Subsystem ZVx1043.0009.50 3.76 E-153.6.14 SENSe SubsystemThe SENSe subsystem is divided up into several subsystems. The commands of these subsys
ZVx SENSe Subsystem1043.0009.50 3.77 E-15[:SENSe[1 to 4]:]AVERage:MODEThe command selects the type of the average function.Syntax: [:SENSe[1 to 4]:]AV
SENSe Subsystem ZVx1043.0009.50 3.78 E-153.6.14.3 SENSe:CORRection SubsystemThe SENSe:CORRection subsystem controls the system error correction and th
ZVx SENSe Subsystem1043.0009.50 3.79 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:N<50|75>:MMTHrough:MFTHrough:FFTHro
SENSe Subsystem ZVx1043.0009.50 3.80 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:N<50|75>:MFSNetwork:FFSNetwork:MOPe
Contents ZVx1127.8700.12 20 E-3Annex B – List of Error Messages...
ZVx SENSe Subsystem1043.0009.50 3.81 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:N<50|75>:MREFlect:FREFlect:MMTCh:FM
SENSe Subsystem ZVx1043.0009.50 3.82 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:SMA:SELect:MMTHrough:MFTHrough:FFTHrough:
ZVx SENSe Subsystem1043.0009.50 3.83 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:SMA:MMSNetwork:MFSNetwork:FFSNetwork:MOPe
SENSe Subsystem ZVx1043.0009.50 3.84 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:SMA:FSHort:MREFlect:FREFlect:MMTCh:FMTCh:
ZVx SENSe Subsystem1043.0009.50 3.85 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:PC<7|35|292>:SELect:MMTHrough:MFTHr
SENSe Subsystem ZVx1043.0009.50 3.86 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:PC<7|35|292>:MMSNetwork:MFSNetwork:
ZVx SENSe Subsystem1043.0009.50 3.87 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:PC<7|35|292>:FSHort:MREFlect:FREFle
SENSe Subsystem ZVx1043.0009.50 3.88 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:USER<1|2>:SELect:IMPedance:WGUide[:
ZVx SENSe Subsystem1043.0009.50 3.89 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:USER<1|2>:MMSNetwork:MFSNetwork:FFS
SENSe Subsystem ZVx1043.0009.50 3.90 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:CKIT:USER<1|2>:FSHort:MREFlect:FREFlect:
ZVx Figures1127.8700.12 21 E-3FiguresFig. 3-1 Tree structure of the SCPI command systems: The SENSe system ... 3.9F
ZVx SENSe Subsystem1043.0009.50 3.91 E-15COMMAND PARAMETER UNIT COMMENT [SENSe<1...4>]:CORRection:EDELay<1|2>[:TIME]:DISTance:ELENgth:DIEL
SENSe Subsystem ZVx1043.0009.50 3.92 E-15[SENSe[1...4]:]CORRection:AKAL:CLEarThis command clears the selected data set for the AutoKal box. The suffix
ZVx SENSe Subsystem1043.0009.50 3.93 E-15[SENSe[1...4]:]CORRection:COLLect:METHodThis command defines the calibration method. Syntax:[SENSe[1...4]:
SENSe Subsystem ZVx1043.0009.50 3.94 E-15[SENSe[1...4]:]CORRection:CKIT:INSTallThe command installs a calibration kit data set from a file.Syntax:[SEN
ZVx SENSe Subsystem1043.0009.50 3.95 E-15[SENSe[1...4]:]CORRection:CKIT:<CAL-Kit-Typ>:SELectThis command selects a defined calibration kit from
SENSe Subsystem ZVx1043.0009.50 3.96 E-15Two-port standards are either MM = connector/connector, FF = socket/socket or MF =connector/socket, one-port
ZVx SENSe Subsystem1043.0009.50 3.97 E-15[SENSe[1...4]:]CORRection:EDELay[1|2]:ELENgthThis command defines the length offset as an electrical length.S
SENSe Subsystem ZVx1043.0009.50 3.98 E-15[SENSe[1...4]:]CORRection:OFFSet[1|2]:MAGNitudeThis command defines the amplitude offset.Syntax:[SENSe[1...4]
ZVx SENSe Subsystem1043.0009.50 3.99 E-15The table below shows the correction terms available for the calibration methods:Calibration Method Available
SENSe Subsystem ZVx1043.0009.50 3.100 E-15[SENSe[1...4]:]CORRection:POWer:DATAThis command is used for reading and writing power correction values for
Tables ZVx1127.8700.12 22 E-3TablesTable 3-1 Synchronisation using *OPC *OPC? and *WAI...
ZVx SENSe Subsystem1043.0009.50 3.101 E-153.6.14.4 SENSe:DETector SubsystemDas SENSe:DETector-subsystem controls how the analyzer takes measurement da
SENSe Subsystem ZVx1043.0009.50 3.102 E-153.6.14.5 SENSe:FREQuency SubsystemThe SENSe:FREQuency subsystem controls the frequency abscissa of the activ
ZVx SENSe Subsystem1043.0009.50 3.103 E-15[SENSe[1 to 4]:]FREQuency:CENTerThis command defines the center frequency of the analyzer.Syntax: [SENSe[1 t
SENSe Subsystem ZVx1043.0009.50 3.104 E-15[SENSe[1...4]:]FREQuency:MODEThis command determines which command groups are used for setting the frequency
ZVx SENSe Subsystem1043.0009.50 3.105 E-15[SENSe[1...4]:]FREQuency:CONVersion:MIXer:FUNDamentalFor mixer measurements, this command selects the fundam
SENSe Subsystem ZVx1043.0009.50 3.106 E-15[SENSe[1...4]:]FREQuency:CONVersion:MIXer:TFRequency.This command determines the sign of the third mixer fre
ZVx SENSe Subsystem1043.0009.50 3.107 E-153.6.14.6 SENSe:FUNCtion SubsystemThe SENSe:FUNCtion-Subsystem defines the measurement function performed by
SENSe Subsystem ZVx1043.0009.50 3.108 E-15"XFRequency:NLINear:TOI:CHECk:LEVel ON | OFF""XFRequency:NLINear:TOI:CHECk:IPNoise ON | OFF&q
ZVx SENSe Subsystem1043.0009.50 3.109 E-153.6.14.7 SENSe:ROSCillator - SubsystemDieses Subsystem controls the reference oscillator. COMMAND PARAMETER
SENSe Subsystem ZVx1043.0009.50 3.110 E-153.6.14.8 SENSe:SEGMent SubsystemThe SENSe:SEGMent-Subsystem defines the parameter for a segmented sweep. COM
ZVx Index1127.8700.12 I.1 E-3IndexNote: All softkeys are listed with their names. The page numbers 2.xxx refer to the detaileddescription of the softk
ZVx SENSe Subsystem1043.0009.50 3.111 E-15[SENSe[1...4]:]SEGMent:CLEarThis command deletes all segmentsSyntax:[SENSe[1...4]:]SEGMent:CLEarExample:&quo
SENSe Subsystem ZVx1043.0009.50 3.112 E-153.6.14.9 SENSe:SWEep SubsystemThis subsystem controls the sweep parameters. COMMAND PARAMETER UNIT COMMENT[S
ZVx SENSe Subsystem1043.0009.50 3.113 E-15[SENSe[1 to 4]:]SWEep:POINtsThis command defines the number of measured points in one sweep.Syntax: [SENSe[1
SOURce Subsystem ZVx1043.0009.50 3.114 E-153.6.15 SOURce SubsystemThe SOURce subsystem directly controls device-specific settings which are necessary
ZVx SOURce Subsystem1043.0009.50 3.115 E-15 COMMAND PARAMETER UNIT COMMENTSOURce<1...4>:POWer:CENTer:SPAN:STARt:STOP
SOURce Subsystem ZVx1043.0009.50 3.116 E-15SOURce<1...4>:POWer[:LEVel][:IMMediate]:CAMPlitude:A<1|2>This command defines the level of the
ZVx SOURce Subsystem1043.0009.50 3.117 E-15SOURce[1...4]: POWer:ALC[:STATe]This command is for controlling the ALC loop of the analyzer. With ON the i
SOURce Subsystem ZVx1043.0009.50 3.118 E-15SOURce[1...4]:POWer:NLINear:SOI:RANGe:LOWerThis command defines a lower limit for the power of the signal s
ZVx SOURce Subsystem1043.0009.50 3.119 E-15SOURce<1...4>: POWer:SPANThis command defines the level display range of the analyzer in the level sw
SOURce Subsystem ZVx1043.0009.50 3.120 E-15SOURce<1...4>: POWer:CORRection:EXT<1|2>:SWEepThis command defines the sweep parameters to be u
Index ZVx1127.8700.12 I.2 E-3BOTH PORTS (REFL NORM, ZVR)...2.335, 3.93BRIGHTNESS ...
ZVx SOURce Subsystem1043.0009.50 3.121 E-15SOURce<1...4>: POWer:CORRection:LLISt:STATeThis command defines whether the power loss list should be
SOURce Subsystem ZVx1043.0009.50 3.122 E-15SOURce[1...4]:FREQuency:NLINear:COMPThis command specifies whether the internal signal source or one of the
ZVx STATus Subsystem1043.0009.50 3.123 E-153.6.16 STATus SubsystemThe STATus subsystem contains the commands for the status-reporting system (see Sect
STATus Subsystem ZVx1043.0009.50 3.124 E-15STATus:OPERation:CONDition?This command queries the CONDition section of the STATus:OPERation register.Synt
ZVx STATus Subsystem1043.0009.50 3.125 E-15STATus:QUEStionable[:EVENt?]This command queries the contents of the EVENt section of the STATus:QUEStionab
STATus Subsystem ZVx1043.0009.50 3.126 E-15 STATus:QUEStionable:FREQuency[:EVENt?]This command queries the contents of the EVENt section of the STATus
ZVx STATus Subsystem1043.0009.50 3.127 E-15STATus:QUEStionable:LIMit[:EVENt?]This command queries the contents of the EVENt-section of the STATus:QUES
STATus Subsystem ZVx1043.0009.50 3.128 E-15 STATus:QUEStionable:POWer[:EVENt?]This command queries the contents of the EVENt section of the STATus:QUE
ZVx STATus Subsystem1043.0009.50 3.129 E-15STATus:QUEue[:NEXT?]This command queries the earliest entry to the error queue, thus deleting it.Syntax: ST
SYSTem Subsystem ZVx1043.0009.50 3.130 E-153.6.17 SYSTem SubsystemThe SYSTem subsystem lists commands for general functions. COMMAND PARAMETER UNIT CO
ZVx Index1127.8700.12 I.3 E-3DATA SET LIST (RECALL) ...2.179DATA SET LIST/CONTENTS (RECALL) (selection table)...
ZVx SYSTem Subsystem1043.0009.50 3.131 E-15COMMAND PARAMETER UNIT COMMENT:PRESet:SET:TIME:VERSion?--<block>0...23, 0...59, 0...59 --query onlySY
SYSTem Subsystem ZVx1043.0009.50 3.132 E-15SYSTem:COMMunicate:GPIB:RDEVice:GENerator<1|2>:ADDRessThis command changes the IEC-bus address of the
ZVx SYSTem Subsystem1043.0009.50 3.133 E-15SYSTem:COMMunicate:PRINter<1|2>:SELect <printer_name>This command selects one of the printers
SYSTem Subsystem ZVx1043.0009.50 3.134 E-15SYSTem:COMMunicate:RDEVice:GENerator<1|2>:TYPEThis command selects the type of external generator.Syn
ZVx SYSTem Subsystem1043.0009.50 3.135 E-15SYSTem:COMMunicate:RDEVice:PMETer:CFACtor:ASENsorThis command defines the sensor factor list for sensor A w
SYSTem Subsystem ZVx1043.0009.50 3.136 E-15SYSTem:COMMunicate:SERial<1|2>:CONTrol:DTRSYSTem:COMMunicate:SERial<1|2>:CONTrol:RTSThese comma
ZVx SYSTem Subsystem1043.0009.50 3.137 E-15SYSTem:COMMunicate:SERial<1|2>[:RECeive]:SBITsThis command defines the number of stopbits per data wo
SYSTem Subsystem ZVx1043.0009.50 3.138 E-15SYSTem:ERRor[:NEXT]?This command queries and at the same time deletes the oldest entry in the error queue.S
ZVx SYSTem Subsystem1043.0009.50 3.139 E-15SYSTem:PRESetThis command triggers an instrument reset.Syntax: SYSTem:PRESetExample: "SYST:PRES"F
TRACe Subsystem ZVx1043.0009.50 3.140 E-153.6.18 TRACe SubsystemThe TRACe subsystem controls access to the instrument’s internal trace memory. COMMAND
Index ZVx1127.8700.12 I.4 E-3ELECTRICAL LENGTH (OFFSET)... 2.372, 3.97Electrostatic discharge...
ZVx TRACe Subsystem1043.0009.50 3.141 E-15TRACe:COPYThis command copies the trace data of the active channel to one of the 8 memory traces.Syntax: TRA
TRACe Subsystem ZVx1043.0009.50 3.142 E-15 TRACe[:DATA][:RESPonse]:BODY?This query command reads the response values of the trace data from the devic
ZVx TRACe Subsystem1043.0009.50 3.143 E-15TRACe:FEEDThis command transfers data from the internal memory traces to the channel specific memories forme
TRIGger-Subsystem ZVx1043.0009.50 3.144 E-153.6.19 TRIGger-SubsystemThe TRIGger subsystem is used to synchronize tasks performed by the instrument and
ZVx TRIGger-Subsystem1043.0009.50 3.145 E-15TRIGger[:SEQuence]:HOLDoffThis command defines the length of the trigger delay.Syntax:TRIGger[:SEQuence]:H
Instrument Model and Command Processing ZVx1043.0009.50 3.146 E-153.7 Instrument Model and Command ProcessingThe model shown in Fig. 3-2 visualizes t
ZVx Instrument Model and Command Processing1043.0009.50 3.147 E-153.7.2 Command RecognitionThe command recognition analyses the data received from the
Instrument Model and Command Processing ZVx1043.0009.50 3.148 E-153.7.5 Output UnitThe output unit collects the information requested by the controlle
ZVx Status Reporting System1043.0009.50 3.149 E-153.8 Status Reporting SystemThe status reporting system (cf. Fig. 3-4) stores all information on the
Status Reporting System ZVx1043.0009.50 3.150 E-15CONDition part The CONDition part is directly written into by the hardware or the sum bit ofthe next
ZVx Index1127.8700.12 I.5 E-3GATE START... 2.105, 2.114, 3.20, 3.41GATE STOP... 2.105, 2.1
ZVx Status Reporting System1043.0009.50 3.151 E-153.8.2 Overview of the Status RegistersSRESTBSTATus:OPERation RegisterPPEIST flag(answer to parallel
Status Reporting System ZVx1043.0009.50 3.152 E-153.8.3 Description of the Status Registers3.8.3.1 Status Byte (STB) and Service Request Enable Regi
ZVx Status Reporting System1043.0009.50 3.153 E-153.8.3.2 IST Flag and Parallel Poll Enable Register (PPE)By analogy with the SRQ, the IST flag combi
Status Reporting System ZVx1043.0009.50 3.154 E-153.8.3.4 STATus:OPERation RegisterIn the CONDition part, this register contains information on which
ZVx Status Reporting System1043.0009.50 3.155 E-153.8.3.5 STATus:QUEStionable-RegisterThis register contains information on questionable instrument st
Status Reporting System ZVx1043.0009.50 3.156 E-153.8.3.6 STATus:QUEStionable:LIMit RegisterThis register provides information about whether a limit v
ZVx Status Reporting System1043.0009.50 3.157 E-153.8.4 Application of the Status Reporting SystemIn order to be able to effectively use the status r
Status Reporting System ZVx1043.0009.50 3.158 E-153.8.4.3 Parallel PollIn a parallel poll, up to eight instruments are simultaneously requested by the
ZVx Status Reporting System1043.0009.50 3.159 E-153.8.5 Reset Values of the Status Reporting SystemTable 3-7 comprises the different commands and eve
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.160 E-153.9 Softkeys and Related IEC/IEEE BUS CommandsThe following list contains the IEC/IEEE-bus
Index ZVx1127.8700.12 I.6 E-3LIN SWEEP... 2.193, 3.104, 3.113Lin/Logdisplay...
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.161 E-15KEEP STOPFREQCALCulate:TRANsform:TIME:LPASs KFSTopKEEP FREQSTEP WIDTHCALCulate:TRANsform:TI
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.162 E-15DEFMIXER MEAS--RF=BASE FREQSENSe[1...4]:FREQuency:CONVersion:MIXer:FUNDamental RFLO=BASE F
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.163 E-15INT SRCSOURce[1..4]:FREQuency:NLINear:COMP INTEXT SRC1SOURce[1..4]:FREQuency:NLINear:COMP E
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.164 E-15SWEEP MODE--FREQUENCYSWEEPSENSe[1..4]:FUNCtion[:ON] ‘XFR:POW:...’TIMESWEEPSENSe[1..4]:FUNCt
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.165 E-15SERVICEFUNCTIONDIAGnostic:SERVice:FUNCtion <num>,<num>,<num>,<num>,
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.166 E-153.9.2 COPY Key GroupCOPYHCOPy[:IMMediate<1|2>]SETTINGS--COPYSCREENHCOPy:ITEM:ALLCOPY
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.167 E-153.9.3 MEMORY Key GroupCONFIGEDITPATHMMEMory:MSIS <device>MMEMory:CDIRectory <dire
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.168 E-15PAGE UP--PAGE DOWN--EDITCOMMENTMMEMory:COMMent <string>ASCIIFILE--ASCIIFORMat:DEXport
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.169 E-15RECALL--EDITNAMEMMEMory:LOAD:STATe 1,<file_name>SET PATHA:\...MMEMory:CDIRectory ‘A:\
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.170 E-153.9.5 STIMULUS Key GroupSTARTSENSe[1..4]:FREQuency:STARt <numeric_value> (Frequenzsw
ZVx Index1127.8700.12 I.7 E-3frequency sweep ...2.138frequency-converting measurements...
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.171 E-15DEF TRIGGER--IMMEDIATETRIGger[:SEQuence]:SOURce IMMediateEXTERNALTRIGger[:SEQuence]:SOURce
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.172 E-15SOURCE--POWERSOURce:POWer[:LEVel][:IMMediate][:AMPLitude] <numeric_value>SLOPESOURce:
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.173 E-15AVERAGERESTARTSENSe[1..4]:AVERage:CLEarIFBANDWIDTH[SENSe[1...4]:]BANDwidth|BWIDth[:RESoluti
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.174 E-15GROUPDELAYCALCulate[1..4]:MARKer[1..8]:FORMat GDELayLIN MAGAND PHASECALCulate[1..4]:MARKer[
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.175 E-15DEFINEB’DFILTER--BANDPASSCALCulate[1...4]:MARKer[1...8]:FUNCtion:BWIDth:MODE BPASsBANDSTOP
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.176 E-153.9.8 CHANNEL Key GroupCH1..CH4INSTrument[:SELect] CHANNEL<1..4>3.9.9 RESPONSE Key
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.177 E-15COMPLEXCONVERSSCALCulate[1...4]:TRANsform:COMPlex S1/SCALCulate[1...4]:TRANsform:COMPlex
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.178 E-15LCALCulate[1...4]:FORMat LCCALCulate[1...4]:FORMat CPHASEUNWRAPCALCulate[1...4]:FORMat UPHa
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.179 E-15CHARTERDISPlay[:WINDow<1...4>]:DIAGram CHARterDISPLAY--SINGLECHANNELDISPlay:FORMat SI
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.180 E-153.9.10 CAL Key GroupCAL--STARTNEW CAL--FULLTWO PORT--PORT 1CONNECTOR--N 50 ΩFEMALE[SENSe[1
Index ZVx1127.8700.12 I.8 E-3PORT 2 (REFL NORM, ZVR) ...2.335PORT1/PORT2...
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.181 E-15MATCHPORT 2[SENSe[1...4]:]CORRection:COLLect[:ACQuire] MATCH2SLIDEPORT 1[SENSe[1...4]:]CORR
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.182 E-15TNA[SENSe[1...4]:]CORRection:COLLect:METHod TNATHROUGH(TNA)[SENSe[1...4]:]CORRection:COLLec
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.183 E-15AUTOKALFUNDAM´TAL[SENSe[1...4]:]CORRection:COLLect:METHod FUNDamentalFULLONE PORT-- (ZVR, Z
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.184 E-15ONE PATHTWO PORT(ZVR, ZVRE, ZVC, ZVCE)FORWARD[SENSe[1...4]:]CORRection:COLLect:METHod FOPTp
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.185 E-15TRANS NORMFORWARD[SENSe[1...4]:]CORRection:COLLect:METHod FTRANSREVERSE[SENSe[1...4]:]CORRe
Softkeys – IEC/IEEE-bus-commands ZVx1043.0009.50 3.186 E-15TRANS NORM[SENSe[1...4]:]CORRection:COLLect:METHod FTRans(ZVRL)FORWARD[SENSe[1...4]:]CORRec
ZVx Softkeys – IEC/IEEE-bus-commands1043.0009.50 3.187 E-15START NEWPOWER CAL--CALa1 POWERSOURce:POWer[:LEVel][:IMMediate]:CAMPlitude:A1 <numeric_v
ZVx Selftest1043.0009.50 4.1 E-34 Maintenance and Troubleshooting4.1 Maintenance4.1.1 Mechanical MaintenanceThe network analyzer does not require any
Selbsttest ZVx1043.0009.50 4.2 E-34.2 Monitoring the Function4.2.1 Switch-on TestAfter the instrument has been switched on, a self test of the proces
ZVx Index1127.8700.12 I.9 E-3display...2.52, 2.53ordinate ...
ZVx Selftest1043.0009.50 4.3 E-34.3 Function Description of the Complete InstrumentThe members of the ZVR/ZVC families are vector network analyzers w
Selbsttest ZVx1043.0009.50 4.4 E-3The ZVRL, on the other hand, is a unidirectional network analyzer with only oneSWR bridge without RF switch. Therefo
ZVx Selftest1043.0009.50 4.5 E-34.3.1.5 LocalThe Local module provides the LO signals for the two mixers in the front end channels (LO1 signal forthe
Selbsttest ZVx1043.0009.50 4.6 E-34.3.3 Processor StructureIn addition to a 586 CPU, the network analyzer also comprises three 32-bit transputers T805
ZVx Selftest1043.0009.50 4.7 E-34.4 Self testThe current firmware version does not support an automatic self test yet.However, the necessary hardware
ZVx Measuring Instruments and Accessories 1043.0009.50 5.1 E-7 5 Testing the Rated Specifications 5.1 Measuring Instruments and Accessories (R&
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.2 E-7 5.2 Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) The
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.3 E-7 Measurement Set test frequencies according to test report. Mea
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.4 E-7 Measurement: Set test frequencies according to test report. Mix
Index ZVx1127.8700.12 I.10 E-3SoftkeyENABLE DEV1 / DEV2...2.163GENERAL SETUP ...
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.5 E-7 5.2.1.5 Residual FM Test equipment: Modulation meter FMB, matchi
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.6 E-7 Reference measurement: with Opt. B10 CENTER 100MHz Port 1: -
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.7 E-7 Measurement: Set test frequencies and levels according to test re
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.8 E-7 Alternative Measurement for R&S ZVR (firmware version 1.50 and
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.9 E-7 Measurement: Set test frequencies according to test report. Rea
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.10 E-7 Measurement: Set test frequencies and levels according to test r
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.11 E-7 5.2.2.4 Matching Input b1 and Input b2 (Only with Option Extern
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.12 E-7 Alternative Measurement (firmware version 1.50 and higher):Test eq
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.13 E-7 5.2.3 Testing the Test Set Specifications 5.2.3.1 Matching t
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.14 E-7 • R&S ZVRL Measurement PORT2: Measurement PORT1 As with R&a
ZVx Index1127.8700.12 I.11 E-3TOM-X... 2.314, 3.93TOSM...
ZVx Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.15 E-7 5.2.3.3 Testing the Attenuators Test equipment: Connecting cabl
Test Sequence (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.16 E-7 5.2.3.4 Crosstalk Test equipment: 2 N-short-circuits (SHORT mal
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.17 E-7 5.3 Performance Test Report (R&S ZVR, R&S ZVR
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.18 E-7 Item No. Characteristic Measure according to section
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.19 E-7 Item No. Characteristic Measure according to section
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.20 E-7 Item No. Characteristic Measure according to section
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.21 E-7 Item No. Characteristic Measure according to section
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.22 E-7 Item No. Characteristic Measure according to section
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.23 E-7 Item No. Characteristic Measure according to section
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.24 E-7 Table 5-2 Performance Test Report: Receiver specificat
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.25 E-7 Item No. Characteristics Measurementaccording to secti
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.26 E-7 Item No. Characteristics Measurementaccording to secti
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.27 E-7 Item No. Characteristics Measurementaccording to secti
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.28 E-7 Item No. Characteristics Measurementaccording to secti
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.29 E-7 Item No. Characteristics Measurementaccording to secti
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.30 E-7 Item No. Characteristics Measurementaccording to secti
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.31 E-7 Table 5-3 Performance Test Report: Test Set Specificati
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.32 E-7 Item No. Characteristics Measurement according to sect
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.33 E-7 Item No. Characteristics Measurement according to sect
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.34 E-7 Item No. Characteristics Measurement according to sect
1043.0009.50 S.1 E-5Important Hints before Operation:For all instruments:• The directory C:\R_S\INSTR and its subdirectories are reserved for system s
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.35 E-7 Item No. Characteristics Measurement according to sect
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.36 E-7 Item No. Characteristics Measurement according to sect
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.37 E-7 Item No. Characteristics Measurement according to sect
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.38 E-7 Item No. Characteristics Measurement according to sect
ZVx Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) 1043.0009.50 5.39 E-7 Table 5-4 Performance Test Report: Crosstalk Item No.
Performance Test Report (R&S ZVR, R&S ZVRE, R&S ZVRL) ZVx 1043.0009.50 5.40 E-7 Item No. Characteristics Measurementaccording to secti
ZVx Measuring Instruments and Accessories (ZVC, ZVCE) 1043.0009.50 5.41 E-7 5.4 Measuring Instruments and Accessories (ZVC, ZVCE) Item Type of I
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.42 E-7 5.5 Test Sequence (R&S ZVC, R&S ZVCE) The rated specifications of the
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.43 E-7 Measurement Set test frequencies according to test report. Measure at twic
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.44 E-7 Measurement: Set test frequencies according to test report. Mixer range up
1043.0009.50 S.2 E-5Patent InformationThis product contains technology licensed by Marconi Instruments LTD. under US patents 4609881 and4870384 and un
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.45 E-7 5.5.1.5 Residual FM est equipment: Modulation meter FMB Test setup: Conne
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.46 E-7 5.5.1.7 Level Linearity Test equipment: Power meter NRVD with power sensor NR
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.47 E-7 5.5.1.8 Matching to Output a1 (Only with Option R&S ZVR-B25, External M
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.48 E-7 5.5.2 Testing the Receiver Specifications 5.5.2.1 Absolute Accuracy Test eq
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.49 E-7 5.5.2.2 Linearity Test equipment: Attenuator RSM Test setup: Connect RSM be
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.50 E-7 60 dB to 70 dB (ZVCE) <1 dB <6°60 dB to 75 dB (ZVC) <1 dB
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.51 E-7 Measurement: Set test frequencies according to test report. Read marker valu
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.52 E-7 Reference measurement: One-port calibration including THRU over the complete fr
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.53 E-7 5.5.3 Testing the Test Set Specifications 5.5.3.1 Matching to PORT1 and PO
Test Sequence (R&S ZVC, R&S ZVCE) ZVx 1043.0009.50 5.54 E-7 Reference measurement: Perform reflection normalization (CAL menu) at PORT1 or P
1171.0000.42-02.00 Sheet 1 Before putting the product into operation for the first time, make sure to read the following Safety Instructions Roh
ZVx Test Sequence (R&S ZVC, R&S ZVCE) 1043.0009.50 5.55 E-7 Permissible deviations: ATT a1, a2 ATT b1, b2 < 2 dB < 2 dB 5.5.3.4
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.56 E-7 5.6 Performance Test Report (ZVC, ZVCE) Table 5-5: Performance Test Report – Gener
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.57 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.58 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.59 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.60 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.61 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.62 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.63 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.64 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
ZVx Tabbed Divider Overview1127.8700.12 RE E-1Volume 1 Volume 2Contents ContentsIndex IndexData SheetSupplementsSafety Instructions Safety Instruction
Safety Instructions 1171.0000.42-02.00 Sheet 2 Observing the safety instructions will help prevent personal injury or damage of any kind caused by d
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.65 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.66 E-7 Item No. Characteristics Measuremt.according to section Min. value Actual value M
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.67 E-7 Table 5-6 Performance Test Report: Receiver Specifications Item No. Characteristic
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.68 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.69 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.70 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.71 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.72 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.73 E-7 Table 5-7 Performance Test Report: Test Set Specifications Item No. Characteristics
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.74 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Safety Instructions 1171.0000.42-02.00 Sheet 3 4. If products/components are mechanically and/or thermically processed in a manner that goes beyond
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.75 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.76 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.77 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.78 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.79 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.80 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.81 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.82 E-7 Table 5-8 Performance Test Report: Crosstalk Item No. Characteristics Measuremt. a
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.83 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.84 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Safety Instructions 1171.0000.42-02.00 Sheet 4 19. If a product is to be permanently installed, the connection between the PE terminal on site and t
ZVx Performance Test Report (ZVC, ZVCE) 1043.0009.50 5.85 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
Performance Test Report (ZVC, ZVCE) ZVx 1043.0009.50 5.86 E-7 Item No. Characteristics Measuremt. according to section Min. value Actual value
ZVx Measuring Equipment and Accessories (ZVM, ZVK)1127.8500.60 5.1 E-25 Checking of Rated Specifications5.1 Measuring Equipment and Accessories (ZVM
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.2 E-25.2 Test Procedure (ZVM & ZVK)The rated specifications of the network analyzer are checked
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.3 E-25.2.1.2 HarmonicsTest equipment: FSEK30, test cableTest setup: ½ Connect FSEK30 (delta-marker m
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.4 E-25.2.1.3 SpuriousTest equipment: FSEK30, test cableTest setup: ½ Connect FSEK30 (delta-marker mo
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.5 E-25.2.1.4 Phase NoiseTest equipment:Modulation meter FMB with option FMA-B8, FSEK30, BNC connectin
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.6 E-25.2.1.5 Residual FMTest equipment:Modulation meter FMB with option FMA-B8, FSEK30, BNC connectin
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.7 E-25.2.1.6 Level AccuracyTest equipment: Power Meter NRVD with sensor NRV-Z52 (ZVM), NRV-Z55 (ZVK),
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.8 E-25.2.1.7 Level LinearityTest equipment: FSEK30, test cable, BNC cable for reference frequencyTest
1171.0000.42-02.00 página 1 Por favor lea imprescindiblemente antes de la primera puesta en funcionamiento las siguientes informaciones de segurid
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.9 E-25.2.2 Checking the Receiver Specifications5.2.2.1 Absolute AccuracyTest equipment: Signal Gener
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.10 E-25.2.2.2 LinearityTest equipment: 20 dB attenuator PC 3.5, SMA (ZVM) or PC 2.92 (ZVM, ZVK),Test
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.11 E-25.2.2.3 Noise LevelTest equipment: MATCH female from Calibration Kit ZV-Z32 (ZVM) or ZV-Z34 (ZV
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.12 E-25.2.2.4 Match Input b1 and Input b2(only with option ZVM-B23 / ZVK-B23 or ZVM-B24 / ZVK-B24)Te
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.13 E-25.2.3 Checking the Test Set Specifications5.2.3.1 Match at PORT1 and PORT2Test equipment: Cal
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.14 E-25.2.3.2 Matching Reference Channel Inputs R1 and R2 Channel INTest equipment: Calibration Kit
ZVx Test Procedure (ZVM & ZVK)1127.8500.60 5.15 E-25.2.3.3 Raw DirectivityTest equipment: OPEN, SHORT, MATCH female from Calibration Kit ZV-Z32 (Z
Test Procedure (ZVM & ZVK) ZVx1127.8500.60 5.16 E-25.2.3.4 Checking the AttenuatorsTest equipment: Test Cable ZV-Z14, female-female adapter PC 3.
ZVx1127.8500.60 5.17 E-25.2.3.5 Dynamic RangeTest equipment: ZVM: 2 PC 3.5 SHORT (e.g. SHORT male and SHORT female with THRU malefrom Calibration Kit
Performance Test Record (ZVM) ZVx1127.8500.60 5.18 E-25.3 Performance Test Record (ZVM)The indicated uncertainties refer to the proposed test setup /
Informaciones de seguridad 1171.0000.42-02.00 página 2 Tener en cuenta las informaciones de seguridad sirve para tratar de evitar daños y peligros d
ZVx Performance Test Record (ZVM)1127.8500.60 5.19 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVM) ZVx1127.8500.60 5.20 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVM)1127.8500.60 5.21 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVM) ZVx1127.8500.60 5.22 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVM)1127.8500.60 5.23 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVM) ZVx1127.8500.60 5.24 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVM)1127.8500.60 5.25 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVM) ZVx1127.8500.60 5.26 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVM)1127.8500.60 5.27 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVM) ZVx1127.8500.60 5.28 E-2Item Characteristic Measure-ment acc.to sectionMeasuredvalue/HzSpecificationmax.value/HzUncer-ta
Informaciones de seguridad 1171.0000.42-02.00 página 3 seguridad (control a primera vista, control de conductor protector, medición de resistencia d
ZVx Performance Test Record (ZVM)1127.8500.60 5.29 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBmMeasuredvalue/dBmSpecif
Performance Test Record (ZVM) ZVx1127.8500.60 5.30 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.31 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.32 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.33 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.34 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.35 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.36 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.37 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.38 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Informaciones de seguridad 1171.0000.42-02.00 página 4 12. No utilice nunca el producto si está dañado el cable eléctrico. Asegure a través de las m
ZVx Performance Test Record (ZVM)1127.8500.60 5.39 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.40 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.41 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.42 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.43 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.44 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specifica
ZVx Performance Test Record (ZVM)1127.8500.60 5.45 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specifica
Performance Test Record (ZVM) ZVx1127.8500.60 5.46 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.47 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.48 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specifica
Informaciones de seguridad 1171.0000.42-02.00 página 5 27. Baterías y acumuladores no deben de ser expuestos a temperaturas altas o al fuego. Guarda
ZVx Performance Test Record (ZVM)1127.8500.60 5.49 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specifica
Performance Test Record (ZVM) ZVx1127.8500.60 5.50 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.51 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.52 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.53 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.54 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.55 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.56 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.57 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.58 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
1127.8600.01-1- CE E-2EC Certificate of ConformityCertificate No.: 2000-05, page 1This is to certify that:Equipment type Stock No. DesignationZVC 1127
ZVx Performance Test Record (ZVM)1127.8500.60 5.59 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.60 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.61 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.62 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.63 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.64 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.65 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.66 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVM)1127.8500.60 5.67 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVM) ZVx1127.8500.60 5.68 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
1127.8600.01-2- CE E-2EC Certificate of ConformityCertificate No.: 2000-05, page 2This is to certify that:Equipment type Stock No. DesignationZVK-B21
ZVx Performance Test Record (ZVM)1127.8500.60 5.69 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.70 E-25.4 Performance Test Record (ZVK)The indicated uncertainties refer to the proposed test setup /
ZVx Performance Test Record (ZVK)1127.8500.60 5.71 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.72 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.73 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.74 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.75 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.76 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.77 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.78 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Introduction/Brief Instructions1043.0009.50 3.1 E-153 Remote Control3.1 IntroductionThe instrument is equipped with two IEC/IEEE bus interfaces ac
ZVx Performance Test Record (ZVK)1127.8500.60 5.79 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.80 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.81 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.82 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.83 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.84 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.85 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
Performance Test Record (ZVK) ZVx1127.8500.60 5.86 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBcMeasuredvalue/dBcUncer-
ZVx Performance Test Record (ZVK)1127.8500.60 5.87 E-2Item Characteristic Measure-ment acc.to sectionMeasuredvalue/HzSpecificationmax. valueHzUncer-ta
Performance Test Record (ZVK) ZVx1127.8500.60 5.88 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBmMeasuredvalue/dBmSpecif
Switchover to Remote Control ZVx1043.0009.50 3.2 E-153.3 Switchover to Remote ControlOn power-on, the instrument is always in the manual operating st
ZVx Performance Test Record (ZVK)1127.8500.60 5.89 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin.value/dBmMeasuredvalue/dBmSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.90 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVK)1127.8500.60 5.91 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.92 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVK)1127.8500.60 5.93 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.94 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVK)1127.8500.60 5.95 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.96 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Performance Test Record (ZVK)1127.8500.60 5.97 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.98 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
ZVx Switchover to Remote Control1043.0009.50 3.3 E-153.3.1.3 Return to Manual OperationReturn to manual operation is possible via the front panel or
ZVx Performance Test Record (ZVK)1127.8500.60 5.99 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecifi
Performance Test Record (ZVK) ZVx1127.8500.60 5.100 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.101 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.102 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.103 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.104 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.105 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.106 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
ZVx Performance Test Record (ZVK)1127.8500.60 5.107 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
Performance Test Record (ZVK) ZVx1127.8500.60 5.108 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
Switchover to Remote Control ZVx1043.0009.50 3.4 E-153.3.2.3 Return to Manual OperationReturn to manual operation is possible via the front panel or
ZVx Performance Test Record (ZVK)1127.8500.60 5.109 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
Performance Test Record (ZVK) ZVx1127.8500.60 5.110 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.111 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.112 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.113 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.114 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
ZVx Performance Test Record (ZVK)1127.8500.60 5.115 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
Performance Test Record (ZVK) ZVx1127.8500.60 5.116 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
ZVx Performance Test Record (ZVK)1127.8500.60 5.117 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/°Measuredvalue/°Specific
Performance Test Record (ZVK) ZVx1127.8500.60 5.118 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Switchover to Remote Control1043.0009.50 3.5 E-153.3.3.2 Unix EnvironmentIn order to access the measuring equipment via the RSIB interface, copy t
ZVx Performance Test Record (ZVK)1127.8500.60 5.119 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.120 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.121 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.122 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.123 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.124 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.125 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.126 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.127 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.128 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Messages ZVx1043.0009.50 3.6 E-153.4 MessagesThe messages transferred via the data lines of the IEC bus or via the RSIB Interface (see annex A) canbe
ZVx Performance Test Record (ZVK)1127.8500.60 5.129 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.130 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.131 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.132 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.133 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
Performance Test Record (ZVK) ZVx1127.8500.60 5.134 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Performance Test Record (ZVK)1127.8500.60 5.135 E-2Item Characteristic Measure-ment acc.to sectionSpecificationmin. value/dBMeasuredvalue/dBSpecif
ZVx Interfaces1043.0009.50 A.1 E-8Annex A - InterfacesA.1 IEC Bus Interface (SCPI IEC625, SYSTEM BUS)The standard network analyzer is equipped with tw
Interfaces ZVx1043.0009.50 A.2 E-8Bus Lines1. Data bus with 8 lines DIO 1 to DIO 8.The transmission is bit-parallel and byte-serial in the ASCII/ISO c
ZVx Messages1043.0009.50 3.7 E-153.4.3 Device Messages (Commands and Device Responses)Device messages are transferred on the data lines of the IEC bu
ZVx Interfaces1043.0009.50 A.3 E-8Interface FunctionsInstruments which can be remote controlled via the IEC bus can be equipped with different interfa
Interfaces ZVx1043.0009.50 A.4 E-8Universal CommandsThe universal commands are encoded 10 - 1F hex. They affect all instruments connected to the buswi
ZVx Interfaces1043.0009.50 A.5 E-8A.2 RS-232-C Interface (COM1, COM2)The standard instrument is equipped with two serial interfaces (RS-232-C). The RS
Interfaces ZVx1043.0009.50 A.6 E-82. Control linesDCD (Data Carrier Detect),Not used in this instrument.Input; active LOW.Using this signal, the local
ZVx Interfaces1043.0009.50 A.7 E-8Interface FunctionsFor interface control, several strings are defined and control characters are reserved which are
Interfaces ZVx1043.0009.50 A.8 E-8Hardware handshakeFor hardware handshake, the instrument indicates that it is ready to receive data via the lines DT
ZVx Interfaces1043.0009.50 A.9 E-8A.3 RSIB InterfaceThe instrument is equipped with an RSIB interface as standard, which enables controlling of theins
Interfaces ZVx1043.0009.50 A.10 E-8The RSIB directory also contains the program RSIBCNTR.EXE with which SCPI commands can be sentto the instrument via
ZVx Interfaces1043.0009.50 A.11 E-8RSIB Interface FunctionsThis chapter lists all functions of the DLL "RSIB.DLL" or "RSIB32.DLL"
Interfaces ZVx1043.0009.50 A.12 E-8Count variable - ibcntlThe variable ibcntl is updated with the number of bytes transmitted on every read and write
Structure and Syntax of the Device Messages ZVx1043.0009.50 3.8 E-153.5 Structure and Syntax of the Device Messages3.5.1 SCPI IntroductionSCPI (Stand
ZVx Interfaces1043.0009.50 A.13 E-8Description of Interface FunctionsRSDLLibfind()The function provides a handle for access to the device with the nam
Interfaces ZVx1043.0009.50 A.14 E-8RSDLLilwrtThis function sends Cnt bytes to a device with the handle ud.VB format: Function RSDLLilwrt (ByVal ud%, B
ZVx Interfaces1043.0009.50 A.15 E-8RSDLLibrd()The function reads data from the device with the handle ud into the string Rd.VB format: Function RSDLLi
Interfaces ZVx1043.0009.50 A.16 E-8RSDLLibrdf()Reads data from the device with the handle ud into the file file.VB format: Function RSDLLibrdf (ByVal
ZVx Interfaces1043.0009.50 A.17 E-8RSDLLibsreThis function sets the device to the ’LOCAL’ or ’REMOTE’ state.VB format: Function RSDLLibsre (ByVal ud%,
Interfaces ZVx1043.0009.50 A.18 E-8RSDLLibrspThis function performs a serial poll and provides the status byte of the device.VB format: Function RSDLL
ZVx Interfaces1043.0009.50 A.19 E-8RSDLLTestSRQThis function checks the status of the SRQ bit.VB format: Function RSDLLTestSrq (ByVal ud%, Result%, ib
Interfaces ZVx1043.0009.50 A.20 E-8RSDLLSwapBytesThis function changes the display of binary numbers on non-Intel platforms.VB format: Not provided at
ZVx Interfaces1043.0009.50 A.21 E-8A.4 User Interface (USER)The user interface, located on the rear panel of the ZVx, is a 25 pin Cannon connector whi
Interfaces ZVx1043.0009.50 A.22 E-8A.5 Printer Interface (LPT)The 25-pin LPT connector on the rear panel of the ZVx is provided for the connection of
ZVx Structure and Syntax of the Device Messages1043.0009.50 3.9 E-15Device-specific commandsHierarchy: Device-specific commands are of hierarchical st
ZVx Interfaces1043.0009.50 A.23 E-8A.6 Probe Connectors (PROBE 1, PROBE 2)To allow the connection of probes, the ZVx has the supply voltage connectors
Interfaces ZVx1043.0009.50 A.24 E-8A.12 Connectors for Controlling an External Generator of theR&S Family SME / SMP and other (BLANK, TRIGGER)A sp
ZVx Interfaces1043.0009.50 A.25 E-8A.15 Mouse Connector (MOUSE)123456Pin Signal1 MOUSEDATA2NC3 MOUSEGND4 MOUSEVD55 MOUSECLK6NCFig A-8 Pin assignments
ZVx List of Error Messages1043.0009.50 B.1 E-1Annex B – List of Error MessagesThe following list contains all error messages for errors occurring in t
List of Error Messages ZVx1043.0009.50 B.2 E-1Continuation: Command ErrorError code Error text in the case of queue pollError explanation-109Missing p
ZVx List of Error Messages1043.0009.50 B.3 E-1Continuation: Command ErrorError codeError text in the case of queue pollError explanation-144Character
List of Error Messages ZVx1043.0009.50 B.4 E-1Execution Error - Error on execution of a command; sets bit 4 in the ESR registerError code Error text i
ZVx List of Error Messages1043.0009.50 B.5 E-1Continuation: Execution ErrorError code Error text in the case of queue pollError explanation-230Data co
List of Error Messages ZVx1043.0009.50 B.6 E-1Continuation: Execution ErrorError code Error text in the case of queue pollError explanation-270Macro e
Structure and Syntax of the Device Messages ZVx1043.0009.50 3.10 E-15Optional key words: Some command systems permit certain key words to be optionall
ZVx List of Error Messages1043.0009.50 B.7 E-1Device Specific Error; sets bit 3 in the ESR registerError code Error test in the case of queue pollErro
ZVx List of Commands1043.0009.50 C.1 E-15Annex C – List of CommandsCommand Parameters PageCALCulate[1...4]: FILTer[:GATE]:TIME:STARt <numeric_value
List of Commands ZVx1043.0009.50 C.2 E-15Command Parameters PageCALCulate[1...4]:MARKer[1...8]:FUNCtion:DELTa:REFerence:RPOSition:POLar<numeric_val
ZVx List of Commands1043.0009.50 C.3 E-15Command Parameters PageCALCulate[1...4]:TRANSform:TIME:XAXisTIME | DISTance | HDIStance 3.42CALCulate[1...4]:
List of Commands ZVx1043.0009.50 C.4 E-15Command Parameters PageHCOPy:ITEM:PFEed[1|2]:STATe ON | OFF 3.58HCOPy:ITEM:WINDow[1...4]:TRACe[1|2]:LTYPe SOL
ZVx List of Commands1043.0009.50 C.5 E-15Command Parameters PageMMEMory:SELect[:ITEM]:HWSettings ON|OFF 3.69MMEMory:SELect[:ITEM]:LINes[:ALL] ON|OFF 3
List of Commands ZVx1043.0009.50 C.6 E-15Command Parameters Page[SENSe[1...4]:]CORRection:CKIT:PC[7|35] MMTHrough | MFTHrough | FFTHrough | MMLINE1 |F
ZVx List of Commands1043.0009.50 C.7 E-15Command Parameters Page[SENSe[1...4]:]FREQuency:NLINear:COMP:STIMe <numeric_value> 3.106[SENSe[1...4]:
List of Commands ZVx1043.0009.50 C.8 E-15Command Parameters PageSOURce<1...4>:POWer:CORRection:LLISt <numeric_value>,<numeric_value>
ZVx Contents1127.8700.12 13 E-3Contents3 Remote Control ...
ZVx Structure and Syntax of the Device Messages1043.0009.50 3.11 E-153.5.3 Structure of a Command LineA command line may consist of one or several co
ZVx List of Commands1043.0009.50 C.9 E-15Command Parameters PageSYSTem:COMMunicate:GPIB:RDEVice:PMETer:ADDRess 0...30 3.132SYSTem:COMMunicate:GPIB:RDE
List of Commands ZVx1043.0009.50 C.10 E-15Command Parameters PageTRACe[:DATA]:STIMulus:BODY? CH1DATA | CH2DATA | CH3DATA |CH4DATA |CH1MEM | CH2MEM | C
ZVx Programming Examples1043.0009.50 D.1 E-2Annex D – Programming ExamplesThe following examples explain the programming of the instrument and can ser
Programming Examples ZVx1043.0009.50 D.2 E-2D.3 Transmission of Instrument Setting CommandsCenter frequency, span, and reference level of the analyzer
ZVx Programming Examples1043.0009.50 D.3 E-2D.7 Command synchronizationThe possibilities for synchronization implemented in the following example are
Programming Examples ZVx1043.0009.50 D.4 E-2D.8 Service RequestThe service request routine requires an extended initialization of the instrument in wh
ZVx Programming Examples1043.0009.50 D.5 E-2Reading out the status event registers, the output buffer and the error/event queue is effected insubrouti
Programming Examples ZVx1043.0009.50 D.6 E-2D.9 Programming via the RSIB InterfaceThe following hints apply to both the 16-bit and the 32-bit DLL vers
ZVx Programming Examples1043.0009.50 D.7 E-2Example:Dim ibsta As Integer ’ Status variableDim iberr As Integer ’ Error variableD
Programming Examples ZVx1043.0009.50 D.8 E-2• In this example, a Save/Recall of the instrument setups is performed. Dim ibsta As Integer ’ Statu
Structure and Syntax of the Device Messages ZVx1043.0009.50 3.12 E-153.5.5 ParametersMost commands require a parameter to be specified. The parameters
ZVx Programming Examples1043.0009.50 D.9 E-2Programming example:• Using the macro QueryMaxPeak a single sweep with subsequent query of the maximum pe
Programming Examples ZVx1043.0009.50 D.10 E-2D.9.3 C / C++Programming hints:• Access to the functions of the RSIB32.DLL (Windows platforms)The functi
ZVx Programming Examples1043.0009.50 D.11 E-2Programming example:In the following C program example, a single sweep is started on the device with the
ZVx Mouse Control1043.0009.50 E.1 E-4Annex E - EmulationsE.1 Mouse Control of Display ElementsThe network analyzer can be optionally equipped with a m
External Keyboard ZVx1043.0009.50 E.2 E-4E.2 Front Panel Keyboard EmulationThe network analyzer can be equipped with an optional external keyboard (se
ZVx Structure and Syntax of the Device Messages1043.0009.50 3.13 E-15Text Text parameters observe the syntactic rules for key words, i.e. they can bee
Description of Commands ZVx1043.0009.50 3.14 E-153.6 Description of Commands3.6.1 NotationIn the following sections, all commands implemented in the
ZVx Description of Commands1043.0009.50 3.15 E-15Special characters | A selection of key words with an identical effect exists for severalcommands. Th
Description of Commands ZVx1043.0009.50 3.16 E-15<numeric_value><num> These indications mark parameters which may be entered as numericval
ZVx Common Commands1043.0009.50 3.17 E-153.6.2 Common CommandsThe common commands are taken from the IEEE 488.1 (IEC 625-2) standard. Same commands ha
Common Commands ZVx1043.0009.50 3.18 E-15*CAL?CALIBRATION QUERY triggers a calibration of the instrument and subsequently query thecalibration status.
ZVx Common Commands1043.0009.50 3.19 E-15*PRE 0 to 255PARALLEL POLL REGISTER ENABLE sets parallel poll enable register to the value indicated.Query *P
CALCulate Subsystem ZVx1043.0009.50 3.20 E-153.6.3 CALCulate SubsystemThe CALCulate subsystem contains commands for converting instrument data, transf
Contents ZVx1127.8700.12 14 E-33.6.3.5 CALCulate:MARKer Subsystem... 3.293.6.3.6 CAL
ZVx CALCulate Subsystem1043.0009.50 3.21 E-15CALCulate[1...4]:FILTer[:GATE]:TIME:SPANThis command defines the span of the gate.Syntax:CALCulate[1...4]
CALCulate Subsystem ZVx1043.0009.50 3.22 E-153.6.3.2 CALCulate:FORMat SubsystemThe CALCulate:FORMat subsystem specifies the display format of the meas
ZVx CALCulate Subsystem1043.0009.50 3.23 E-153.6.3.3 CALCulate:GDAPerture SubsystemThe CALCulate:GDAPerture - subsystem defines the parameters for the
CALCulate Subsystem ZVx1043.0009.50 3.24 E-153.6.3.4 CALCulate:LIMit SubsystemThe CALCulate:LIMit subsystem comprises the limit lines and the correspo
ZVx CALCulate Subsystem1043.0009.50 3.25 E-15CALCulate[1...4]:LIMit[1...8]: RDOMain:COMPlexThis command defines the complex conversion of the measured
CALCulate Subsystem ZVx1043.0009.50 3.26 E-15CALCulate[1..4]:LIMit[1...8]:CONTrol:SHIFtThis command shifts a limit line along the x-axis direction by
ZVx CALCulate Subsystem1043.0009.50 3.27 E-15CALCulate[1...4]:LIMit[1...8]:UPPer:STATeThis command switches on and off the limit check with an upper l
CALCulate Subsystem ZVx1043.0009.50 3.28 E-15CALCulate[1...4]:LIMit[1...8]:FAIL?This command queries the result of the limit check.Syntax:CALCulate[1.
ZVx CALCulate Subsystem1043.0009.50 3.29 E-153.6.3.5 CALCulate:MARKer SubsystemThe CALCulate:MARKer subsystem controls the marker functions. COMMAND P
CALCulate Subsystem ZVx1043.0009.50 3.30 E-15CALCulate[1 to 4]:MARKer[1 to 8][:STATe]This command switches on or off the selected marker (1 to 8). If
ZVx Contents1127.8700.12 15 E-33.8.3.1 Status Byte (STB) and Service Request Enable Register (SRE)... 3.1523.8.3.2 IST Flag and Parallel
ZVx CALCulate Subsystem1043.0009.50 3.31 E-15CALCulate[1 to 4]:MARKer[1 to 8]:XThis command positions the selected marker to the indicated stimulus va
CALCulate Subsystem ZVx1043.0009.50 3.32 E-15CALCulate[1...4]:MARKer[1...8]:SEARch[:IMMediate]This command triggers a search for absolute extreme valu
ZVx CALCulate Subsystem1043.0009.50 3.33 E-15CALCulate[1...4]:MARKer[1...8]:MAXimumThis command triggers the search for the maximum of the trace for t
CALCulate Subsystem ZVx1043.0009.50 3.34 E-15CALCulate[1...4]:MARKer[1...8]:FUNCtion:QFACtorThis command defines the quality factor for the marker sea
ZVx CALCulate Subsystem1043.0009.50 3.35 E-15CALCulate[1...4]:MARKer[1...8]:FUNCtion:EDELay:VALue?This command queries the value of the electrical or
CALCulate Subsystem ZVx1043.0009.50 3.36 E-15CALCulate[1...4]:MARKer[1...8]:FUNCtion:PTPeak:STATeThis command switches the determination of the maximu
ZVx CALCulate Subsystem1043.0009.50 3.37 E-15CALCulate[1...4]:MARKer[1...8]:FUNCtion:REFerenceThis command sets the reference level to the current mar
CALCulate Subsystem ZVx1043.0009.50 3.38 E-153.6.3.6 CALCulate:MATH SubsystemThe CALCulate:MATH - Subsystem allows to process data from the SENSe-subs
ZVx CALCulate Subsystem1043.0009.50 3.39 E-153.6.3.7 CALCulate:SMOothing SubsystemThe CALCulate:SMOothing - Subsystem allows to smooth a data set poin
CALCulate Subsystem ZVx1043.0009.50 3.40 E-153.6.3.8 CALCulate:TRANsform SubsystemThe CALCulate:TRANsform subsystem defines the transformation of data
Contents ZVx1127.8700.12 16 E-34 Maintenance and Troubleshooting... 4
ZVx CALCulate Subsystem1043.0009.50 3.41 E-15CALCulate[1...4]:TRANsform:TIME:METHodThis command selects the transformation method (fast Fourier or chi
CALCulate Subsystem ZVx1043.0009.50 3.42 E-15CALCulate[1...4]:TRANsform:TIME:STOPThis command defines the stop time for the time domain transformation
ZVx CALCulate Subsystem1043.0009.50 3.43 E-153.6.3.9 CALCulate:UNIT SubsystemThe CALCulate:UNIT - subsystem defines the physical units to be used for
DIAGnostic Subsystem ZVx1043.0009.50 3.44 E-153.6.4 DIAGnostic SubsystemThe DIAGnostic subsystem contains the commands which support instrument diagno
ZVx DISPlay Subsystem1043.0009.50 3.45 E-153.6.5 DISPlay SubsystemThe DISPLay subsystem controls the selection and presentation of textual and graphic
DISPlay Subsystem ZVx1043.0009.50 3.46 E-15DISPlay:FORMat:EXPandThis command switches the expanded representation on or off.Syntax:DISPlay:FORMat:EXPa
ZVx DISPlay Subsystem1043.0009.50 3.47 E-15DISPlay[:WINDow[1...4]]:DIAGram:SEGMented:RThis command defines the segment limits for polar diagrams. A ma
DISPlay Subsystem ZVx1043.0009.50 3.48 E-15DISPlay[:WINDow[1 to 4]]:TRACe[1|2]:Y[:SCALe]:RLEVelThis command defines the reference level. In addition t
ZVx DISPlay Subsystem1043.0009.50 3.49 E-15DISPlay[:WINDow[1 to 4]]:TRACe[1|2]:Y[:SCALe]:BOTTomThis command defines the lower edge of the grid. In add
DISPlay Subsystem ZVx1043.0009.50 3.50 E-15DISPlay[:WINDow[1 to 4]]:TRACe[1|2]:Y[:SCALe]:OFFSetThis command defines an offset value to be added to the
ZVx Contents1127.8700.12 17 E-3Contents5 Testing the Rated Specifications...
ZVx DISPlay Subsystem1043.0009.50 3.51 E-15DISPlay[:WINDow[1 to 4]:TRACe[1|2][:STATe]This command switches the display of the current trace on or off.
FORMat Subsystem ZVx1043.0009.50 3.52 E-153.6.6 FORMat SubsystemThe FORMat subsystem specifies the format of the data transmitted from and to the anal
ZVx FORMat Subsystem1043.0009.50 3.53 E-15FORMat:DEXPortThis command defines the format of the file to be generated.Syntax:FORMat:DEXPort ASCii | TOUC
FORMat Subsystem ZVx1043.0009.50 3.54 E-15FORMat:DEXPort:SOURceThis command defines the source of measurement data. Syntax:FORMat:DEXPort:SOURce CD
ZVx HCOPy Subsystem1043.0009.50 3.55 E-153.6.7 HCOPy SubsystemThe HCOPy subsystem controls the output of screen information to output devices or files
HCOPy Subsystem ZVx1043.0009.50 3.56 E-15HCOPy:ABORtThis command aborts an active print job.Syntax: HCOPy:ABORtExample: "HCOP:ABOR"Features:
ZVx HCOPy Subsystem1043.0009.50 3.57 E-15HCOPy:DEVice:LANGuage<1|2>This command determines the data format of the printout.Syntax:HCOPy:DEVice:L
HCOPy Subsystem ZVx1043.0009.50 3.58 E-15HCOPy:ITEM:ALLThis command selects the complete screen to be output.Syntax: HCOPy:ITEM:ALLExample: "HCOP
ZVx HCOPy Subsystem1043.0009.50 3.59 E-15HCOPy:ITEM:WINDow<1...4>:TEXTThis command selects the comment text for printout to trace 1 or 2.Syntax:
HCOPy Subsystem ZVx1043.0009.50 3.60 E-15HCOPy:ITEM:WINDow[1...4]:TRACe[1|2]:LTYPe:AINCrementThis command causes automatic incrementation of the line
Comments to this Manuals