Epson Stylus CX8400 Service Manual Page 135

  • Download
  • Add to my manuals
  • Print
  • Page
    / 159
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 134
EPSON Stylus CX7300/CX7400/DX7400/NX200/TX200 series/SX200 series/Stylus CX8300/CX8400/DX8400/NX400/TX400 series/SX400 series Revision C
DISASSEMBLY/ASSEMBLY Disassembling the Scanner Unit 135
Confidential
Front Scanner Housing
1. Remove the Upper Scanner Housing toward you. (p134)
2. Release the hooks at the bottom of the Upper Scanner Housing, and remove
the Front Scanner Housing.
Figure 4-106. Removing the Front Scanner Housing
4.6.2 Scanner Carriage Unit
Parts/Components need to be removed in advance
Document Cover/ASF Cover/Scanner Unit/Upper Scanner Housing
Removal procedure
1. Move the Scanner Carriage Unit to the center.
Figure 4-108. Moving the Scanner Carriage Unit
Bottom
Upper Scanner Housing
Hook
Front Scanner Housing
C A U T I O N
Do not scratch the Rod Lens Array when removing the Scanner
Carriage Unit.
Figure 4-107. Handling the Scanner Carriage Unit
Rod Lens Array
Scanner Carriage Unit