EPSON ELP-3500 Service Manual
3-17
3.2.11 Removing the Power Supply Unit
Prerequisite: Complete the steps explained in sections 3.2.1 and 3.2.4.
Screws
Power Supply Cables
Figure 3-20.
1. Remove 2 lamp power supply cables connected with the lamp’s inner housing unit
screws.
Screws: +M3x8 F/Zn: P-Tight P/N 1021824
Mounting torque: 6.0 kg cm = 5.2 lb inch
2. Disconnect the cables (blue/white) from the safety switch.
3. Remove 4 mounting screws from the power supply unit.
Screws: +M3x8 F/Zn: P/N 1021824
Mounting torque: 6.0 kg cm = 5.2 lb inch
4. Remove the ground cable mounting screw.
Screw: +M4x6 F/Ni: P/N 1033025
Mounting torque: 6.0 kg cm = 5.2 lb inch
5. Pull the power supply unit straight up with the inlet cover.
Caution:
When removing the power supply unit, take care not to bend or damage the bosses on
the lower case unit. When installing the power supply unit, align the power supply unit by
positioning holes with these bosses. The intake fan and its peripheral parts in the power
supply unit are susceptible to dust and dirt. When installing the power supply unit, check
the fan's cleanness and clean it if necessary.
Page view 67