Table A-30.
Stylus Color 740 EEPROM Address Map (Coutinued)
Address Explanation Setting
QPIT
Settings
Factory
Settings
14H Head actuator
rank ID for lwEF
00H (*1)
15H Bi-D Adjustment
data for Normal-
dot
-36<=n=<+36
(by 1/1440 inch)
00H (*1)
16H Bi-D Adjustment
data for Micro-dot
-36<=n=<+36
(by 1/1440 inch)
00H (*1)
17H Bi-D Adjustment
data for Variable-
dot
-36<=n=<+36
(by 1/1440 inch)
00H (*1)
18H Uni-D adjustment
data
-36<=n=<+36
(by 1/1440 inch)
00H (*1)
19H Reserved for
adjustment data
00H -
1AH Reserved for
adjustment data.
00H -
1BH 1st dot position
adjustment data
-40<=n=<+40
(by 1/1440 inch)
00H (*1)
1CH Carriage speed
adjustment data
-4<=n<=+4
(by G.A. timer unit)
00H (*1)
1DH Carriage phase
on Home
00H -
1EH Paper sensor
adjustment data
-127<=n<=+127
(by 1/720 inch)
00H (*1)
1FH ERROR Code 00H 00H
20H CPSl password 00H 00H
21H 00H 00H
22H 00H 00H
23H 00H 00H
24H CPSI license flag 0: disable 1: enable 00H 00H
25H CPSl font license 0: disable 1: enable 00H 00H
26H Interface selection 0: Auto, 1: Parallel
2: Serial, 3: USB
00H 00H
(*2)
Table A-31.
Stylus Color 740 EEPROM Address Map (Coutinued)
Address Explanation Setting
QPIT
Settings
Factory
Settings
27H Interface time-out 0 to 255 (by second, value of 0
means 10 seconds)
0AH 0AH
28H Compatibility
speed
0: Fast, 1: Slow
2: Special-1, 3: Special-2
00H 00H
29H ECP speed *
3
0: Fast, 1: Slow 00H 00H
2AH 00H 00H
2BH I/F Control flags bit 1: ECP mode
(0=Off, 1=On) *
4
bit 0: IEEE1284 mode
(0=On, 1=Off) *
5
00H 00H
2CH 00H 01H
2DH Reserved for USB 00H -
2EH Reserved for USB 00H -
2FH Reserved for USB 00H -
30H Font 0: Roman, 1: Sans Serif
2: Courier, 3: Prestige
4: Script, 10: Roman T
11: Sans Serif, 7: Draft
00H 02H
31H Pitch 0: 10 cpi, 1: 12 cpi
2: 15 cpi, 3: 17 cpi
4: 20 cpi, 5: Proportional
00H 00H
32H Print direction
control
0: Bi-D
1: Uni-D
2: Auto
02H 02H
*3: BUSY signal delay time form fall-edge of a -STB signal.
(Fast: Maximum 1MB/s, Slow: Maximum 600KB/s
*4: Select IEEE1284 transfer mode. (ECP or Nibble)
*5: Enable or disable reverse transfer. (When disabled, ignore -SLIN signal