02 AUDIO CONTROL
Command
structure
Type
Apply Reply
STX Size
Attribu
te
FromT
o
Group Item
Param
eter
check-
sum
STX Size
Attribu
te
FromT
o
Group Item
Param
eter
check-
sum
00 : Volume
Controls the volume for the currently-selected audio input.
[Parameter]
Volume Value (1 byte)
Setting range: 00 to 1F
Set
1D 0009 01 FT 02 00 PARA CS 1D
0008
000A
81
C1
FT 02 00
--
PARA
CS
Get
1D 0008 02 FT 02 00 -- CS 1D
0009
000A
82
C2
FT 02 00 PARA CS
Initialize
1D 0008 03 FT 02 00 -- CS 1D
0009
000A
83
C3
FT 02 00 PARA CS
06 : Bass
Controls the bass for the currently-selected audio input.
[Parameter]
Bass Value (1 byte)
Setting range: FA to FF, 00 to 06
Set
1D 0009 01 FT 02 06 PARA CS 1D
0008
000A
81
C1
FT 02 06
--
PARA
CS
Get 1D 0008 02 FT 02 06 -- CS 1D
0009
000A
82
C2
FT 02 06 PARA CS
Initialize 1D 0008 03 FT 02 06 -- CS 1D
0009
000A
83
C3
FT 02 06 PARA CS
07 : Treble
Controls the treble for the currently-selected audio input.
[Parameter]
Treble Value (1 byte)
Setting range: FA to FF, 00 to 06
Set
1D 0009 01 FT 02 07 PARA CS 1D
0008
000A
81
C1
FT 02 07
--
PARA
CS
Get
1D 0008 02 FT 02 07 -- CS 1D
0009
000A
82
C2
FT 02 07 PARA CS
Initialize
1D 0008 03 FT 02 07 -- CS 1D
0009
000A
83
C3
FT 02 07 PARA CS
08 : SRS SPACE (Applicable models: EMP-8100/8150/9100)
Controls the SRS Space level for the currently-selected audio input.
Adjusts the width of hte sound.
[Parameter]
SRS SPACE Value (1 byte)
Setting range: 00 to 06
Set
1D 0009 01 FT 02 08 PARA CS 1D
0008
000A
81
C1
FT 02 08
--
PARA
CS
Get 1D 0008 02 FT 02 08 -- CS 1D
0009
000A
82
C2
FT 02 08 PARA CS
Initialize 1D 0008 03 FT 02 08 -- CS 1D
0009
000A
83
C3
FT 02 08 PARA CS
09 : SRS CENTER (Applicable models: EMP-8100/8150/9100)
Controls the SRS Center level for the currently-selected audio input.
Adjusts the depth of the sound.
[Parameter]
SRS CENTER Value (1 byte)
Setting range: 00 to 06
Set 1D 0009 01 FT 02 09 PARA CS 1D
0008
000A
81
C1
FT 02 09
--
PARA
CS
Get
1D 0008 02 FT 02 09 -- CS 1D
0009
0008
82
C2
FT 02 09 PARA CS
Initialize
1D 0008 03 FT 02 09 -- CS 1D
0009
0008
83
C3
FT 02 09 PARA CS
Page view 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 18 19 20

Comments to this Manuals