6. CONTROL CODE
00 SPECIAL CONTROL
Command
structure
Type
Apply Reply
STX Size
Attribu
te
From
To
Group Item
Param
eter
Check-
sum
STX Size
Attribu
te
From
To
Group Item
Param
eter
Check-
sum
03 : Power
Controls the projector power and gets the present power state.
<In the case of a power on setup of EMP-7600/5600>
Set 1B 07 01 -- 00 03 01 F4 1B 06
81
C1
-- 00 03 -- CS
<In cases other than a power on setup of EMP-7600/5600, and the case of EMP-8100/9100/8150/7700>
[Parameter]
Data relating to the power states.
0x00: PowerOFF
0x01: PowerON
0x02: Suspend
0x10: During Startup
0x11: Cool down
0x20: System fault
* Although setting 0x02 and later in parameter and sending command to the projector, returns NG
in replay. 0x02 and later are available just for informing from the projector.
Set 1D 0009 01 01 00 03
00
01
CS 1D
0008
000A
81
C1
10 00 03
--
PA R A
CS
Get 1D 0008 02 01 00 03 -- CS 1D
0009
000A
82
C2
10 00 03 PA R A CS
06 : Communication rate
Controls the communication rate.
[Parameter]
Data relating to communication rate.
<For EMP-8100/9100/8150/7700>
0x00: 9600bps
0x01: 19200bps
0x02: 38400bps
0x03: 57600bps
<For EMP-7600/5600>
0x00: 9600bps
0x01: 19200bps
0x02: 38400bps
Set
1D 0009 01 01 00 06 PA R A CS 1D
0008
000A
81
C1
10 00 06
--
PA R A
CS
Get
1D 0008 02 01 00 06 -- CS 1D
0009
000A
82
C2
10 00 06 PA R A CS
Initialize 1D 0008 03 01 00 06 -- CS 1D
0009
000A
83
C3
10 00 06 PA R A CS
09 : Lamp Hour
Gets the present lamp hour.
[Parameter]
Returns the present lamp hour (in hours) (2 bytes)
Get
1D 0008 02 01 00 09 -- CS 1D
000A
000A
82
C2
10 00 09 PA R A CS
12 : Error information
Gets and reports projector error information.
[Parameter]
Projector error information
The following data is set with an OR:
0x00: No error or error is cancelled.
0x01: Fan problem
0x04: Internal temperature is abnormally high.
0x08: Lamp life expectancy is closed to end.
0x20: Lamp problem
0x40: Other failures
0x80: Stack failure (EMP-8100/8150/9100 only)
Set
1D 0009 01 01 00 12 -- CS 1D
0008
000A
81
C1
10 00 12
--
PA R A
CS
Get
1D 0008 02 01 00 12 -- CS 1D
0009
000A
82
C2
10 00 12 PA R A CS
}