Cancels all current horizontal tab stops and sets new tab stops every n
columns, where n is between 1 and 127.
Reset all tab stops
Mode
ASCII
Decimal
Hexadecimal
IBM cESC> “R”
27 82 1B 52
Resets the horizontal tab stops to their power-up values in which a tab
stop is set every 8 column starting at column 9. Also clears all vertical
tab stops.
Horizontal tab
Mode ASCII
Decimal Hexadecimal
Both <HT>
9
09
Moves the print position to the next horizontal tab stop. Ignored if there
is no next horizontal tab stop in the current line. Note that when un-
derlining is selected, spaces skipped by horizontal tabulation are not
underlined.
Relative horizontal tab
Mode
ASCII
Decimal Hexadecimal
Std.
< ESC > “r nl n2 27 92 nl n2 1B 5C nl n2
IBM
c FS > “\” nl n2 28 92 nl n2 1C SC nl n2
Moves the print position right or left a specified distance (maximum 6
inches). Ignored if the resulting position is beyond the right or left margin.
The formulas for the distance and direction are as follows:
If n2 is between 0 and 63, the print head moves right by (nr + n2 x 256)/ 120
inches
If n2 is between 64 and 127, the print head moves left by (nl +
[n2- 641 x 256)/120 inches
Absolute horizontal tab in inches
Mode ASCII
Decimal
Hexadecimal
Both I <ESC> “$” nl n2 12736nln2 llB24nln2
Sets the next print position to (nl + n2 x 256)/60 inches from the left
margin on the current line. Ignored if this position is beyond the right
margin. The maximum position is 8 inches.
/