EPSON LQ-670
3/97
To replace the ribbon cartridge, follow these steps:
1. Press the Operate button to turn off the printer and then
open the printer cover.
Warning:
If the printer has been used recently, the print head
may be hot. Let it cool before attempting to replace
the ribbon cartridge.
2. Make sure the print head is at the ribbon installation
position (the middle position where the front metal plate is
indented), as shown below. If the print head is not at this
position, move the print head to the correct position.
Note:
The print head moves to the ribbon installation position
automatically if the printer is on and no data is sent to
the printer for several seconds.
3. Squeeze the tabs on each side of the cartridge, and pull the
cartridge out of the printer.
4. Remove the new ribbon cartridge from its package and turn
the ribbon-tightening knob in the direction of the arrow to
remove any slack in the ribbon.
5. Hold the ribbon cartridge with the exposed ribbon down
and the ribbon-tightening knob facing you, and guide the
ribbon under the print head. Then snap the cartridge into
place so that the tabs on both sides of the cartridge fit into
the notches in the cartridge holder.