28
S-MOS SYSTEMS, INC.
4.0 Commands 4.1 – 4.5
4.1 Display ON/OFF
This command forces all display to turn on or off.
R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0101010111D
Note:
D = 0 Display OFF
D = 1 Display ON
4.2 Display Start Line
This command specifies a line address (shown in
Figure 3.3) thus marking the display line that corre-
sponds to COM0. Display begins with the specified
line address and covers as many lines as match the
display duty in address ascending order. Dynamic
line address change with the Display Start Line com-
mand enables column-wise scrolling or page change.
R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0 1 0 1 1 0 A4 A3 A2 A1 A0
High order bits
A4 A3 A2 A1 A0
Line Address
00000 0
00001 1
↓↓
11111 31
4.3 Set Page Address
This command is used to specify a page address
equivalent to a row address for MPU access to the
display data RAM. A required bit of the display data
RAM can be accessed by specifying its page address
and column address. Changing the page address
causes no change in display.
R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
010101110A1A0
4.4 Column Address
This command specifies a display data RAM column
address. The column address is incremented by 1
each time the MPU accesses from the set address to
the display data RAM. Thus it is possible for the MPU
to gain continuous access to only the data. This
incrementing stops with address 80; the page ad-
dress is not continuously changed.
R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
0 1 0 0 A6 A5 A4 A3 A2 A1 A0
A6 A5 A4 A3 A2 A1 A0
Column
Address
0000000 0
0000001 1
↓↓
1001111 79
4.5 Read Status
R/W
A0 RD WR D7 D6 D5 D4 D3 D2 D1 D0
001
BUSY ADC RESET
0000
Note:
BUSY BUSY being “1” means that system is performing
an internal operation or is reset. No command is
accepted before BUSY = “0”. As long as the cycle
time requirement is met, no BUSY check is needed.
ADC Indicates assignment of column addresses to
segment drivers.
0 : Inverted (column address 79 – n seg-
ment driver n)
1 : Forward (column address n segment
driver n)
ON/OFF Indicates display on or off.
0 : Display on
1 : Display off
This bit has polarity reverse to the Display ON/
OFF command.
RESET Indicates that system is being initialized by the
RES signal or the Reset command.
0 : Display mode
1 : Being reset
ON /
OFF
A1 A0 Page
000
011
A1 A0 Page
102
113
Page view 27