Hardware Functional Specification S1D13705
Issue Date: 02/02/01 X27A-A-001-10
7.1.6 Generic #2 Interface Timing
Figure 7-6: Generic #2 Timing
Note
BCLK may be turned off (held low) between accesses - see Section 13.5, “Turning Off
BCLK Between Accesses” on page 84
Table 7-6: Generic #2 Timing
Symbol Parameter Min Max Units
f
BCLK
Bus Clock frequency 50 MHz
T
BCLK
Bus Clock period 1/f
BCLK
t1 A[16:0], BHE#, CS# valid to WE#, RD# low 0 ns
t2 WE#, RD# high to A[16:0], BHE#,
CS# invalid 0 ns
t3 WE# low to D[15:0] valid (write cycle) T
BCLK
t4 WE# high to D[15:0] invalid (write cycle) 0 ns
t5 RD# low to D[15:0] driven (read cycle) 16 ns
t6 D[15:0] valid to WAIT# high (read cycle) 0 ns
t7 RD# high to D[15:0] high impedance (read cycle) 10 ns
t8 WE#, RD# low to WAIT# driven low 14 ns
t9 BCLK to WAIT# high 10 ns
t10 WE#, RD# high to WAIT# high impedance 11 ns
t11 WAIT# high to WE#, RD# high 1T
BCLK
t8
t4
t9
t3
t1
t10
BCLK
A[16:0]
CS#
WE#,RD#
WAIT#
VALID
t2
Hi-Z
Hi-Z
Hi-Z
VALID
T
BCLK
t6
t7
VALID
Hi-Z
Hi-Z
D[15:0]
D[15:0]
t5
BHE#
(write)
(read)
t11