2-4 Setup Rev. A
2.2.2.1 DIP switch settings for serial interface specifications
Note:
* Factory setting
*1 The baud rate can be changed with the setting values for the communication conditions of
the serial interface. The serial interface communication conditions can be changed using
command. The setting values are 2400, 4800, 9600, 19200, 38400, 57600, and 115200.
The factory default is 115200.
Note:
The values of the communication conditions of the serial interface set with commands are enabled only
when DIP switches 1-7 and 1-8 are On. Otherwise, the value selected with DIP switch 1 has priority.
Table 2-2 Dip Switch bank 1 settings
SW Function ON OFF DEFAULT
1-1 Data receive error Ignore ?” is printed * OFF
1-2 Receive buffer size 45 bytes 4KB * OFF
1-3 Handshake XON/XOFF DTR/DSR * OFF
1-4 Bit length 7 bits 8 bits * OFF
1-5 Parity check Yes No * OFF
1-6 Parity selection Even Odd * OFF
1-7
,
1-8
Baud rate selection
(See the “Baud rate selection” tables below.)
ON
ON
Table 2-3 Baud rate selection (DIP SW1-7, 1-8)
TM-T70
Baud rate (bps)
Switch no.
1-7 1-8
Adjustable by control commands (Default)*1 ON ON
4800 OFF ON
9600 ON OFF
19200 OFF OFF