CONFIDENTIAL
Paper roll Status commands GS a
Ver. 10.05 p. 315
TM-J2000/J2100
The default value is set by Msw1-3.
■ Third byte (paper sensor information)
• When the cover is open, the status of the roll paper end sensor (bit 2, 3) retains the value when the cover
was closed immediately before.
TM-T90
The default value is set by Msw 1-3.
■ Third byte (paper sensor information)
• When the cover is open, the status of the roll paper end sensor (bit 2, 3) retains the value when the cover
was closed immediately before.
TM-L90
TM-L90 with Peeler
The default value is set by Msw 1-3.
The peeling issuing mode and the continuous issuing mode can be selected by a switch. This is a
slide switch that can be used when the roll paper cover is opened.
■ Basic second byte (printer information)
• Bit 0 is changed when GS ^ is executed or when the printer is in one of the following status conditions
when the peeling issuing mode is selected:
■ Waiting for the paper feed button to be pressed with the cover closed.
■ Waiting for the paper feed button to be pressed to remove a label (when the label peeling
detector cannot detect paper due to sunlight)
• If the cause of the recoverable error (bit 2) is the paper layout error, the printer can recover from the error
by opening/closing the roll paper cover or by the DLE ENQ command or pressing the paper feed button
only when memory switch Msw8-1 or Msw8-2 is OFF. See Function 3 of GS E.
■ Basic third byte (paper sensor information)