CONFIDENTIAL
Paper roll Two-dimension code commands GS ( k
Ver. 10.05 p. 565
GS ( k <Function 265>
[Name] MaxiCode: Select the mode
[Format] ASCII GS ( k pL pH cn fn n
Hex 1D 28 6B 03 00 32 41 n
Decimal 2940107305065n
[Range] (pL + pH × 256) = 3 (pL =3, pH =0)
cn = 50
fn = 65
50 ≤ n ≤ 54
[Default] n = 50
[Description] Selects the mode for the MaxiCode
[Notes]
■ Settings of this function affect the processing of Functions 281 and 282.
■ Settings of this function are effective until ESC @ is executed, the printer is reset, or the power is turned
off.
[Model-dependent variations] TM-T90, TM-T88IV, TM-T70, TM-P60
TM-T90, TM-T88IV, TM-T70
This model does not support this function.
TM-P60
TM-P60 with peeler supports this function.
n Function
50 Selects mode 2.
51 Selects mode 3.
52 Selects mode 4.
53 Selects mode 5.
54 Selects mode 6.