Paper roll Customize commands GS ( E
Ver. 10.05 p. 683
(*1) [Communication condition] transmits parameter (a) of this function.
(*2) [Setting value] indicates the setting value of <Function 13> of this command. The currently operating
communication conditions may differ from those before executing <Function 2> of this command.
When (a = 48) is specified, the 6-byte value that expresses the 48-bit BD_ADDR as a hexadecimal is
converted to character data and transmitted from the upper digits. Therefore the BD_ADDR transmission
data consists of the 12-byte data [Hexadecimal = 30H to 39H, 41H to 46H / Decimal = 48 to 57, 65 to 70].
When (a = 49) is specified, the passkey is transmitted. The passkey consists of 4 to 8 bytes of data.
Example: If [Setting value (BD_ADDR)] is 00 03 7A 0C B0 82, the string is the 12 bytes "00037A0CB082"
[Hexadecimal = 30H, 30H, 30H, 33H, 37H, 41H, 30H, 43H, 42H, 30H, 38H, 32H / Decimal = 48, 48, 48, 51, 55,
65, 48, 67, 66, 48, 56, 50].
If [Setting value (passkey)] is 4254, the string is the 4 bytes "4254" [Hexadecimal = 34H, 32H,
35H, 34H / Decimal = 52, 50, 53, 52].
When (a = 65) is specified, the following Header to NUL is transmitted.
(*1) [Communication condition] transmits parameter (a) of this function.
(*2) [Setting value] indicates the setting value of <Function 13> of this command. The currently operating
communication conditions may differ from those before executing <Function 2> of this command.
When (a = 65) is specified the device name is transmitted.
Example: If [Setting value (device name)] is EPSON, the string is the 5 bytes "EPSON" [Hexadecimal = 45H,
50H, 53H, 4FH, 4EH / Decimal = 69, 80, 83, 79, 78].
This function is used to determine whether the settings of <Function 13> have finished normally before
<Function 2> of this command.
Transmit data Hex Decimal Data
Header 37H 55 1 byte
Identifier 7AH 112 1 byte
Identification status 40H 64 1 byte
Communication condition (*1) 41H 65 1 byte
Setting value (*2) 20H – FFH 32 – 255 1–64 byte
NUL 00H 0 1 byte