Paper roll Two-dimension code commands GS ( k
Ver. 10.05 p. 581
If “other information” is “Printing is impossible“(in decimal: 49), use one of the solutions shown below.
See previous [Notes for transmission process] for process sending data group.
[Model-dependent variations] TM-T90, TM-T88IV, TM-T70, TM-L90, TM-P60
TM-T90, TM-T88IV, TM-T70, TM-L90
This model does not support this function.
TM-P60
TM-P60 with peeler supports this function.
In standard mode, when symbols have a height greater than 1,200 dots, they cannot be printed
with this printer according to [Other information] [Hexadecimal = 31H/Decimal = 49].
Cause Solution
There are data in the print buffer
in the standard mode
Put the printer in the “there is no data in the print
buffer” status by executing GS T or print
commands (LF, CR, ESC J).
Symbol is bigger than the current
print area.
Expand the print area by GS W, ESC W, ESC $.
Reduce the module width by Function 367.
There is a problem with the
amount of data or with the data
of the symbol data
Send correct data by Function 380.
There is no data in the symbol
storage area.
Send data to the symbol storage area by Function
380.