Paper roll Customize commands GS ( E
Ver. 10.05 p. 679
(*1) Communication condition transmits the value of a is converted into character data epressed by
decimal numbers. Example: When [Communication condition] is the baud rate (a = 1), it is 1-byte data of
“1” [Hexadecimal = 31H/Decimal = 49].
(*2) “Setting value” is set by Function 11. It might differ from the current communication condition before
executing Function 2 or depending on the setting of the DIP switch. Example: When the baud rate is 9600
bps, it is 4-byte data of “9600” [Hexadecimal = 39H, 36H, 30H, 30H/Decimal = 57, 54, 48, 48].
This function is used to confirm whether Function 11 ends normally before executing Function 2.
See previous [Notes for transmission process] for process sending data group.
Separator 1FH 31 1 byte
Setting value (*2) 30H–39H 48–57 1–5 byte
NUL 00H 0 1 byte