Paper roll Two-dimension code commands GS ( k
Ver. 10.05 p. 567
GS ( k <Function 281>
[Name] MaxiCode: Print the symbol data in the symbol storage area
[Format] ASCII GS ( k pL pH cn fn m
Hex 1D 28 6B 03 00 32 51 m
Decimal 2940107305081m
[Range] (pL + pH × 256) = 3 (pL = 3, pH = 0)
cn = 50
fn = 81
m = 48
[Description] Encodes and prints the MaxiCode symbol data in the symbol storage area using the process of <Function 280>.
[Notes]
In standard mode, use this function when printer is “at the beginning of a line,” or “there is no data in the
print buffer.”
If the symbol size exceeds the print area, the symbol cannot be printed.
If there is any error described below in the data of the symbol storage area, it cannot be printed.
There is no data (Function 180 is not processed).
When using only numeric characters, the data is more than 138 characters.
When using alphanumeric characters, the data is more than 93 characters.
When Mode 2 is selected, the Primary Message includes all data except the following.
Factor of Primary Message Number of data Character
Postal code 1 ~ 9 byte Numeric
ISO country code 1 ~ 3 byte Numeric
Class of service code 1 ~ 3 byte Numeric